Submersible sewage electric pumps are widely used in municipal wastewater treatment,industrial drainage,and residential sewage systems.One common question among engineers,operators,and maintenance personnel is whether a check valve(also known as a non-return valve)is necessary for such pumps.The short answer is:in most cases,yes,but there are important considerations.

What Is a Check Valve and Why Is It Used?

A check valve is a mechanical device that allows fluid to flow in only one direction.When installed on the discharge line of a submersible sewage pump,it prevents backflow when the pump stops.Without a check valve,the column of liquid in the vertical discharge pipe can flow backward through the pump,causing several potential problems:

•Water hammer:Sudden reverse flow can create pressure surges that damage pipes,fittings,and the pump itself.

•Pump impeller reversal:Backflow may cause the impeller to spin backwards,which can loosen threaded components or damage bearings over time.

•Sump flooding:In sewage applications,backflow can refill the wet well or sump,defeating the purpose of pumping and potentially leading to overflow.

•Sediment accumulation:Solids in sewage can settle back into the pump housing,increasing the risk of clogging during the next start.

Typical Applications Where a Check Valve Is Required

In most municipal and industrial sewage lift stations,building codes and standard engineering practice mandate the installation of a check valve on each pump discharge line.This is especially critical when:

•The discharge pipe rises vertically to a significant height(e.g.,from a basement sump to ground level).

•Multiple pumps share a common discharge header—without check valves,one running pump could force water back through an idle pump.

•The system relies on gravity drainage after the pump stops;a check valve maintains the prime in the discharge line.

Exceptions and Special Cases

While a check valve is generally recommended,there are scenarios where it might be omitted or replaced with alternative measures:

1.Short horizontal discharge with no elevation change:If the pump discharges directly into an open channel or a large-diameter gravity sewer at nearly the same level,backflow may not cause significant issues.However,this is rare in practice.

2.Pumps designed with built-in anti-backflow features:Some modern submersible sewage pumps incorporate internal mechanisms(such as a spring-loaded flap or a specially shaped volute)that reduce backflow.Even then,an external check valve is often still advised for redundancy.

3.Systems using siphon-breaking devices:In certain temporary or portable setups,a vacuum breaker or air vent can prevent siphoning instead of a check valve.But these solutions are less reliable for permanent installations.

4.Very low head applications with clean liquids:For clear water pumps with negligible solids,the need for a check valve is less critical.However,sewage always contains solids and debris,making backflow more problematic.

Types of Check Valves Suitable for Sewage Pumps

Not all check valves work well with sewage.Standard swing check valves can jam due to solids or rags.The most common choices for sewage applications include:

•Rubber flapper check valves:Flexible rubber disc that seals against a seat;they are less prone to fouling and provide tight shutoff.

•Dual-plate wafer check valves:Compact and lightweight,but may require careful sizing to avoid solids blockage.

•Ball check valves:A ball lifts off its seat under forward flow;suitable for some sewage but can stick if debris accumulates.

•Nozzle-type silent check valves:Designed to minimize water hammer,but more expensive and sensitive to solids.

The valve should be installed horizontally or vertically(as per manufacturer recommendations)and positioned close to the pump discharge to minimize the volume of backflow.

Conclusion

For almost all submersible sewage electric pump installations,a check valve is strongly recommended and often required by code.It protects the pump from reverse rotation,prevents water hammer,reduces clogging risks,and ensures efficient operation of the entire drainage system.While there are niche exceptions,omitting a check valve in a sewage application typically leads to increased maintenance costs,premature pump failure,or system malfunction.

When selecting a check valve,choose a type specifically designed for wastewater with solids-handling capability,and ensure proper sizing to match the pump's flow rate and pipe diameter.With the right valve in place,your submersible sewage pump will operate reliably for years to come.